Pangropéa gun semprot Bab III

Sababaraha masalah kadang muncul dina prosés ngagunakeun gun semprot.Ayeuna urang bakal nganalisis fenomena gun semprot di jéntré, sarta nurutkeun fenomena, analisa alesan jeung manggihan solusi.

Ieu sababaraha kasalahan umum sareng solusi:

kasalahan alesan solusi
Tekanan hawa teu tiasa disaluyukeun normal 1.Rusak regulator hawa atawa klep hawa Ganti AC atanapi klep hawa
  1. Balik cinyusu klep hawa rusak atawa teu dipasang
Ngaganti atawa masang cinyusu balik klep hawa
Palapis bocor tina segel thimble
  1. Cingcin sealing tina pin ejector geus dipaké kaluar
Ngaganti cingcin sealing thimble
  1. Thimble sealing ring gasket teu dipasang
Pasang thimble sealing ring gasket
  1. Thimble sealing ring cinyusu ruksak atawa teu dipasang
Ganti atawa tambahkeun ejector pin segel ring spring
4.Thimble sealing nut geus leupas Tighten nut sealing thimble
5.The kontak antara pin ejector jeung ring sealing dipaké Ngaganti set nozzle
6.Thimble jeung gun semprot teu cocog Ngaganti set nozzle cocog jeung gun semprot

Nozzle peryogi pangropéa, pamariksaan rutin, beberesih sareng bahkan ngagantian, ku kituna pikeun mastikeun kualitas produk ahir sareng ngajaga kauntungan ékonomi tina prosés produksi.Cara sareng frékuénsi prosedur perbaikan gumantung kana aplikasina.

Perawatan sateuacan nyemprot: ngaleungitkeun fosfor, ngaleungitkeun minyak sareng ngaleungitkeun karat.Pariksa naha produk disegel ogé.

214


waktos pos: Aug-16-2022